What should I do if the switch sensor does not work properly?
Firstly, check the following conditions:
1. A load is connected to the switch - a lamp or other device.
2. The switch is connected according to the scheme of a switch or a dimer, a 2 way switch.
3. The backlight of the sensors should work.
Possible causes and how to solve them
№ | Problem | Possible reason | Solution |
1 | The switch does not respond to touch |
The load power is too low, the switch "does not see" it. Significant reactive load connected (transformer, motor, etc.) |
Temporarily, connect an incandescent lamp. If the switch starts to work, you need to install an adapter. Installing the adapter solves the problem 95% of the time. If installing the adapter did not help, you need to additionally install a capacitor. |
2 |
The switch does not work with the glass panel installed. Without panel, the switch works |
The switch sensor is far away from the glass panel. 1) The glass panel may not be firmly installed. 2) When mounting the switch, the metal support was damaged. |
1) slip the sensor closer to the glass panel. 2) replace the metal support. Sensor setup 1. Turn off the voltage! |
3 | The switch does not turn off the light. When the sensor is touched, the relay operation is heard, the LED changes color, but the light does not turn off. | The circuit breaker turned on a load with an inrush current greater than 5 amps (1000 watts). It could be an LED strip with a powerful power supply, a fan, what. Such devices at the time of switching on in the first second consume tens of times more current than during operation. |
The switch should be sent to a service center for testing. LLC Nova Poshta. Recipient LLC LIVOLO UKRAINE, CODE 41264986, Irpin branch 12, tel. 0981515141 company representative. Pay for shipping. Put a note - in the service In order to prevent the problem from reoccurring, we recommend installing a Soft Starter |
4 | The switch automatically turns on or off after a while | Loading power is too small, the switch "does not see" it. Or a significant reactive load is connected (transformer, motor, etc.) |
Temporarily, connect an incandescent lamp. If the switch starts to work, you need to install an adapter. |
5 | No sensor backlight |
1. No load connected 2. The problem with the microcontroller |
1. Check the wiring diagram 2. The switch must be sent to a service center. LLC Nova Poshta. Recipient LLC LIVOLO UKRAINE, CODE 41264986, Irpin branch 12, tel. 0981515141 company representative. Pay for shipping. Put a note - in the service |
6 | The backlight of the sensors changes from blue to red or vice versa, goes out and changes again |
1. Incorrect wiring diagram of the pass switch 2. Light load |
1. For a pass-through switch, check the wiring diagram 2. Increase load or install adapter VL-XA001 |
7 | One of the two switches does not work | Programming gone wrong |
Reset programming: Touch the sensor of the Main switch and hold your finger until the second beep (after about 10 seconds). The programming will be reset. Programming: Step 1: Press the Main Switch sensor and hold your finger until it beeps (about 4-5 seconds). Release your finger from the sensor zones. Step 2: Press the Second Switch sensor for half a second. |